<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
{"version":"1.0","provider_name":"Givi Misure","provider_url":"https:\/\/www.givimisureindia.com","title":"VI900 - Givi Misure","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"SCpZVyUZjL\"><a href=\"https:\/\/www.givimisureindia.com\/index.php\/vi900\/\">VI900<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.givimisureindia.com\/index.php\/vi900\/embed\/#?secret=SCpZVyUZjL\" width=\"600\" height=\"338\" title=\"&#8220;VI900&#8221; &#8212; Givi Misure\" data-secret=\"SCpZVyUZjL\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.givimisureindia.com\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","description":"VI900 \u2013 Multi-axis digital readout, with touch-screen color LCD, for absolute and incremental systems Overview Compact-design, modern and functional digital readout, equipped with the new Absolute Warning System (AWS). AWS constantly guarantees the correctness of the displayed positions and informs the operator of any malfunctioning. The user can continue machining or, based on the error message displayed, intervene to restore the proper functioning of the system. Absolute (SSI protocol) or incremental encoder input signals. 5.7\u201d touch-screen color, LED-backlit, LCD TFT panel which allows the displaying of up to 4 axes. USB, Touch Probe, CAN bus and serial RS-232 interfaces. Resolutions up to 0.1 \u03bcm. Online HELP. Graphic visualization of function execution. Diagnostic of readout and encoders. Reading of coded reference indexes. Absolute signals RS-422: Clock+, Clock-, Data+, Data-. Universal software for any kind of machine tool; updates through serial port. 1000 memory blocks. Possibility of connection to a digital (up to 8 relay outputs) or analog (constant surface speed) remote board. Option: flush-mounted version (on a panel). MODELS VI900 Touch-screen color LCD display RB900 I\/O Digital remote board \u2013 Up to 8 relay outputs New RB900 CSS Analog remote board \u2013 Constant surface speed New VI900 Touch-screen color LCD display Display 5.7\u201d color, LED-backlit LCD TFT Incremental encoder input signals 2 square waves with phase displacementof 90\u00b0 \u00b1 5\u00b0 + synchronized index 5 Vdc Absolute (SSI) encoder input signals RS-422: Clock+, Clock-, Data+, Data- Available resolutions 1,000 \u2013 500 \u2013 200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u20130.5 \u2013 0.2 \u2013 0.1 \u03bcm1\u00b0 \u2013 0.5\u00b0 \u2013 0.2\u00b0 \u2013 0.1\u00b0 \u2013 0.05\u00b0 \u2013 0.02\u00b0 \u2013 0.01\u00b0 \u20130.005\u00b0 \u2013 0.002\u00b0 \u2013 0.001\u00b0 Protection class \u00a0IP 40 IP 54 with plastic cover provided Input axes 2 \u2013 3 \u2013 4 Applicable to lathe \u2013 milling machine \u2013 boring machine \u2013 etc. Power supply 230 Vac \u00b1 10% \u2013 50\/60 Hz 60 mAMAX110 Vac \u00b1 10% \u2013 60 Hz 120 mAMAX24 Vac \u00b1 10% \u2013 50\/60 Hz 500 mAMAX Version standard or flush-mounted Options CAN interface Download Brochure \u2193 RB900 I\/O Digital remote board \u2013 Up to 8 relay outputs New Power supply from VI900 5 Vdc \u00b1 10% \u00a0External power supply (PWS) \u00a012 \u2013 24 Vac \u00b1 10% \u2013 50\/60 Hz12 \u2013 24 Vdc \u00b1 10% \u00a0Power \u00a01.5 WMAX \u00a0Current consumption \u00a0240 mAMAX (5 Vdc from VI900)60 mAMAX (24 Vdc from external power supply PWS) Inputs \u00a0 VinHIGH= 4.5 \u00f7 30 Vdc VinLOW= 0 \u00f7 2 VdctMIN= 100 msoptoisolated and independent \u00a0Digital outputs static N.O. relay contacts, 60 Vac\/dcMAX, 0.6 AMAX,0.36 WMAXprotected against overload and overcurrent Connections D-SUB 15p M (COM1)terminal block 3p M (external power supply PWS)terminal block 12p M (input\/output) Protection class IP 20 Download Brochure \u2193 RB900 CSS Analog remote board \u2013 Constant surface speed New Power supply from VI900 5 Vdc \u00b1 10% \u00a0External power supply (PWS) \u00a012 \u2013 24 Vac \u00b1 10% \u2013 50\/60 Hz12 \u2013 24 Vdc \u00b1 10% \u00a0Power \u00a01.5 WMAX \u00a0Current consumption \u00a0240 mAMAX (5 Vdc from VI900)60 mAMAX (24 Vdc from external power supply PWS) Analog output \u00a00 \u2013 10 Vdc Connections D-SUB 15p M (COM1)terminal block 3p M (external power supply PWS)terminal block 12p M (input\/output) Protection class IP 20 Download Brochure \u2193 ISA 10 Resolution 100 \u00b5m ISA 100 Resolution 10 \u00b5m ISA 5 Resolution 5 \u00b5m ISA W1 Resolution 1 \u00b5m Resolution : 100 \u00b5m Resolution : 10 \u00b5m Resolution : 5 \u00b5m Resolution : 1 \u00b5m Grating pitch : 400 \u00b5m Grating pitch : 40 \u00b5m Grating pitch : 20 \u00b5m Grating pitch : 40 \u00b5m Accuracy grade : \u00b1 10 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Max. traversing speed : 120 m\/min Max. traversing speed : 80 m\/min Max. traversing speed : 60 m\/min Max. traversing speed : 25 m\/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure","thumbnail_url":"https:\/\/techsparktechnologies.in\/givimisure\/wp-content\/uploads\/2026\/01\/v900.png"}