<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
{"version":"1.0","provider_name":"Givi Misure","provider_url":"https:\/\/www.givimisureindia.com","title":"VI700 - Givi Misure","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"OfjZxSuQmq\"><a href=\"https:\/\/www.givimisureindia.com\/index.php\/vi700\/\">VI700<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.givimisureindia.com\/index.php\/vi700\/embed\/#?secret=OfjZxSuQmq\" width=\"600\" height=\"338\" title=\"&#8220;VI700&#8221; &#8212; Givi Misure\" data-secret=\"OfjZxSuQmq\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.givimisureindia.com\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","description":"VI700 \u2013 Multi-axis digital readout, with LED display Overview Compact-design, modern and functional digital readout. Diagnostic of readout and optical scales. Resolutions up to 0.5 \u03bcm. Reading of coded references. Universal software for any kind of machine tool. Software upgrade through serial port. 1,000 memory blocks. Option: flush-mounted version (on a panel). Easy and immediate use of several dedicated functions. MODELS VI518 Standard version VI722L \u2013 VI723LWith 2 displays and LCD VI733 \u2013 VI734 With 3 displays VI733L \u2013 VI734L With 3 displays and LCD VI518 Standard version Display 7 high-efficiency digits h = 17 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 5\u00b0 and zero ref.5 Vdc or 12 Vdc Available resolutions \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u2013 0.5 \u03bcm1\u00b0 \u2013 0.5\u00b0 \u2013 0.2\u00b0 \u2013 0.1\u00b0 \u2013 0.05\u00b0 \u2013 0.02\u00b0 \u2013 0.01\u00b00.005\u00b0 \u2013 0.002\u00b0 \u2013 0.001\u00b0 Protection class \u00a0keyboard IP 67 rear panel IP 42 Input axes 2 \u2013 3 Applicable to lathe \u2013 milling machine \u2013 boring machine \u2013 etc. Power supply 230 Vac \u00b1 10% \u2013 50\/60 Hz 50 mA110 Vac \u00b1 10% \u2013 60 Hz 100 mA24 Vac \u00b1 10% \u2013 50\/60 Hz 450 mA Version standard or flush-mounted Download Brochure \u2193 VI722L \u2013 VI723LWith 2 displays and LCD Display 7 high-efficiency digits h = 17 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 5\u00b0 and zero ref.5 Vdc or 12 Vdc Available resolutions \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u2013 0.5 \u03bcm1\u00b0 \u2013 0.5\u00b0 \u2013 0.2\u00b0 \u2013 0.1\u00b0 \u2013 0.05\u00b0 \u2013 0.02\u00b0 \u2013 0.01\u00b00.005\u00b0 \u2013 0.002\u00b0 \u2013 0.001\u00b0 Protection class \u00a0keyboard IP 67 rear panel IP 42 Input axes 2 \u2013 3 Applicable to lathe \u2013 milling machine \u2013 boring machine \u2013 etc. Power supply 230 Vac \u00b1 10% \u2013 50\/60 Hz 50 mA110 Vac \u00b1 10% \u2013 60 Hz 100 mA24 Vac \u00b1 10% \u2013 50\/60 Hz 450 mA Version standard or flush-mounted Download Brochure \u2193 VI733 \u2013 VI734 With 3 displays Display 7 high-efficiency digits h = 17 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 5\u00b0 and zero ref.5 Vdc or 12 Vdc Available resolutions \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u2013 0.5 \u03bcm1\u00b0 \u2013 0.5\u00b0 \u2013 0.2\u00b0 \u2013 0.1\u00b0 \u2013 0.05\u00b0 \u2013 0.02\u00b0 \u2013 0.01\u00b00.005\u00b0 \u2013 0.002\u00b0 \u2013 0.001\u00b0 Protection class \u00a0keyboard IP 67 rear panel IP 42 Input axes 3 \u2013 4 Applicable to lathe \u2013 milling machine \u2013 boring machine \u2013 etc. Power supply 230 Vac \u00b1 10% \u2013 50\/60 Hz 50 mA110 Vac \u00b1 10% \u2013 60 Hz 100 mA24 Vac \u00b1 10% \u2013 50\/60 Hz 450 mA Version standard or flush-mounted Download Brochure \u2193 VI733L \u2013 VI734L With 3 displays and LCD Display 7 high-efficiency digits h = 17 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 5\u00b0 and zero ref.5 Vdc or 12 Vdc Available resolutions \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u2013 0.5 \u03bcm1\u00b0 \u2013 0.5\u00b0 \u2013 0.2\u00b0 \u2013 0.1\u00b0 \u2013 0.05\u00b0 \u2013 0.02\u00b0 \u2013 0.01\u00b00.005\u00b0 \u2013 0.002\u00b0 \u2013 0.001\u00b0 Protection class \u00a0keyboard IP 67 rear panel IP 42 Input axes 3 \u2013 4 Applicable to lathe \u2013 milling machine \u2013 boring machine \u2013 etc. Power supply 230 Vac \u00b1 10% \u2013 50\/60 Hz 50 mA110 Vac \u00b1 10% \u2013 60 Hz 100 mA24 Vac \u00b1 10% \u2013 50\/60 Hz 450 mA Version standard or flush-mounted Download Brochure \u2193 ISA 10 Resolution 100 \u00b5m ISA 100 Resolution 10 \u00b5m ISA 5 Resolution 5 \u00b5m ISA W1 Resolution 1 \u00b5m Resolution : 100 \u00b5m Resolution : 10 \u00b5m Resolution : 5 \u00b5m Resolution : 1 \u00b5m Grating pitch : 400 \u00b5m Grating pitch : 40 \u00b5m Grating pitch : 20 \u00b5m Grating pitch : 40 \u00b5m Accuracy grade : \u00b1 10 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Max. traversing speed : 120 m\/min Max. traversing speed : 80 m\/min Max. traversing speed : 60 m\/min Max. traversing speed : 25 m\/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure","thumbnail_url":"https:\/\/techsparktechnologies.in\/givimisure\/wp-content\/uploads\/2026\/01\/700.png"}