<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
{"version":"1.0","provider_name":"Givi Misure","provider_url":"https:\/\/www.givimisureindia.com","title":"THESI 310 - Givi Misure","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"qvMe8SleA9\"><a href=\"https:\/\/www.givimisureindia.com\/index.php\/thesi-310\/\">THESI 310<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.givimisureindia.com\/index.php\/thesi-310\/embed\/#?secret=qvMe8SleA9\" width=\"600\" height=\"338\" title=\"&#8220;THESI 310&#8221; &#8212; Givi Misure\" data-secret=\"qvMe8SleA9\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.givimisureindia.com\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","description":"THESI 310 \u2013 Single-axis position controller Overview THESI 310 position controller can control shifting and positioning of one axis in 3 different operating modes: MANUAL, by keyboard; SEMI-AUTOMATIC, by keyboard; AUTOMATIC, on the basis of a memorized program. Possibility of storing up to 99 PROGRAMS with 20 positions each. Up to 99 repetitions can be matched to each position(the program cycle is composed by the position and its respective repetitions). 90 Vac to 230 Vac power supply or 24 Vac power supply with selector. Manufactured with 16 bit microcontroller, 256K FLASH and 8K RAM memory in single-chip mode. Optoisolated inputs: START, STOP, INCREASE CYCLE, DEVIATION, PRESET. Voltage-free contact outputs: ENABLING WITH CONTROL INTERLOCK, OK POSITION, FEED \/ BACK, SLOW \/ FAST. \u00b1 10 Vdc analog output: FEED \/ BACK, SLOW \/ FAST, with linear ramp. Possibility of installation on bench or built in. MODELS THESI 310 DI With relay outputs (digital) THESI 310 AN With anlog output THESI 310 DI With relay outputs (digital) Display POSITION: 6 high-efficiency digits h = 13 mm andnegative sign CYCLES \/ PROGRAMS: 2+2 high-efficiency digits h = 9 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 10\u00b0 and zero ref.5 Vdc or 12 Vdc Axis input frequency \u00a020 kHzMAX \u00a0Linear resolution \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u03bcm \u00a0Protection class \u00a0keyboard IP 65 rear panel IP 40 Power 10 WMAX Power supply 90 to 230 Vac \u00b1 10% \u2013 50\/60 Hz24 Vac \u00b1 10% \u2013 50\/60 Hz Digital outputs N.O. relay contacts Inputs optoisolated Connections by removable terminal block Dimensions front panel: 144\u00d772 mm \u2013 depth: 126 mm Download Brochure \u2193 THESI 310 AN With anlog output Display POSITION: 6 high-efficiency digits h = 13 mm andnegative sign CYCLES \/ PROGRAMS: 2+2 high-efficiency digits h = 9 mm Encoder input signals 2 square waves with phase displacement of 90\u00b0 \u00b1 10\u00b0 and zero ref.5 Vdc or 12 Vdc Axis input frequency \u00a020 kHzMAX \u00a0Linear resolution \u00a0200 \u2013 100 \u2013 50 \u2013 20 \u2013 10 \u2013 5 \u2013 2 \u2013 1 \u03bcm \u00a0Protection class \u00a0keyboard IP 65 rear panel IP 40 Power 10 WMAX Power supply 90 to 230 Vac \u00b1 10% \u2013 50\/60 Hz24 Vac \u00b1 10% \u2013 50\/60 Hz Anlog output \u00b1 10 Vdc optoisolated Inputs optoisolated Connections by removable terminal block Dimensions front panel: 144\u00d772 mm \u2013 depth: 126 mm Download Brochure \u2193 ISA 10 Resolution 100 \u00b5m ISA 100 Resolution 10 \u00b5m ISA 5 Resolution 5 \u00b5m ISA W1 Resolution 1 \u00b5m Resolution : 100 \u00b5m Resolution : 10 \u00b5m Resolution : 5 \u00b5m Resolution : 1 \u00b5m Grating pitch : 400 \u00b5m Grating pitch : 40 \u00b5m Grating pitch : 20 \u00b5m Grating pitch : 40 \u00b5m Accuracy grade : \u00b1 10 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Max. traversing speed : 120 m\/min Max. traversing speed : 80 m\/min Max. traversing speed : 60 m\/min Max. traversing speed : 25 m\/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure","thumbnail_url":"https:\/\/techsparktechnologies.in\/givimisure\/wp-content\/uploads\/2026\/01\/THESI.png"}