<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
{"version":"1.0","provider_name":"Givi Misure","provider_url":"https:\/\/www.givimisureindia.com","author_name":"wpsuperadmin-givimisure","author_url":"https:\/\/www.givimisureindia.com\/index.php\/author\/wpsuperadmin-givimisure\/","title":"GVS 300 - Givi Misure","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"9fiMkEKnYV\"><a href=\"https:\/\/www.givimisureindia.com\/index.php\/gvs-300\/\">GVS 300<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.givimisureindia.com\/index.php\/gvs-300\/embed\/#?secret=9fiMkEKnYV\" width=\"600\" height=\"338\" title=\"&#8220;GVS 300&#8221; &#8212; Givi Misure\" data-secret=\"9fiMkEKnYV\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.givimisureindia.com\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","description":"INCREMENTAL OPTICAL SCALES FOR MACHINE TOOLS Overview Reduced size, to allow installation on small machine-tools or for applications with limited installation space wide cross-section. Dimensions 23x20mm. Possibility of registration which simplifies alignment and allows the use on rough surfaces (retrofitting and machines for which application was not foreseen). Protected against inversion of power supply polarity and short circuits on output ports. Models GVS 300 T05Z GVS 300 TIZ GVS 300 T5Z GVS 300 T1OOZ GVS 300 T05Z Resolution 0.5 \u00b5m Accuracy grade \u00b13\u00b5m Max. traversing speed 12 m\/min Operating Voltage 5Vdc or 12 Vdc \u00b1 5% Output signals NPN \/ LINE DRIVER \/ PUSH -PULL Protection class IP 53 standard IP 64 pressurized Download Brochure \u2193 GVS 300 TIZ Resolution 1 \u00b5m Accuracy grade \u00b1 3 \u00b5m Max. traversing speed 25 m\/min Operating Voltage 5Vdc or 12 Vdc \u00b1 5% Output signals NPN \/ LINE DRIVER \/ PUSH-PULL Protection class IP 53 standard IP 64 pressurized Download Brochure\u2193 GVS 300 T5Z Resolution 5 \u00b5m Accuracy grade \u00b15 pm Max. traversing speed 60m\/min Operating Voltage 5Vdc or 12 Vdc \u00b15% Output signals NPN \/\u00a0 LINE DRIVE \/ PUSH-PULL Protection class IP 53 standard IP 64 pressurized Download Brochure\u2193 GVS 300 T1OOZ Resolution 100 \u00b5m Accuracy grade \u00b15 pm Max. traversing speed 80m\/min Operating Voltage 5Vdc or 12 Vdc \u00b15% Output signals NPN \/\u00a0 LINE DRIVE \/ PUSH-PULL Protection class IP 53 standard IP 64 pressurized Download Brochure\u2193 ISA 10 Resolution 100 \u00b5m ISA 100 Resolution 10 \u00b5m ISA 5 Resolution 5 \u00b5m ISA W1 Resolution 1 \u00b5m Resolution : 100 \u00b5m Resolution : 10 \u00b5m Resolution : 5 \u00b5m Resolution : 1 \u00b5m Grating pitch : 400 \u00b5m Grating pitch : 40 \u00b5m Grating pitch : 20 \u00b5m Grating pitch : 40 \u00b5m Accuracy grade : \u00b1 10 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Accuracy grade : \u00b1 5 \u00b5m Max. traversing speed : 120 m\/min Max. traversing speed : 80 m\/min Max. traversing speed : 60 m\/min Max. traversing speed : 25 m\/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Output signals : NPN \/ LINE DRIVER \/ PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure","thumbnail_url":"https:\/\/techsparktechnologies.in\/givimisure\/wp-content\/uploads\/2026\/01\/2f4b7f30-e1d2-42b8-ab8e-af699b5fb208.png"}