<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Givi Misure</provider_name><provider_url>https://www.givimisureindia.com</provider_url><title>VI900 - Givi Misure</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="gzWTPUs5WT"&gt;&lt;a href="https://www.givimisureindia.com/index.php/vi900/"&gt;VI900&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://www.givimisureindia.com/index.php/vi900/embed/#?secret=gzWTPUs5WT" width="600" height="338" title="&#x201C;VI900&#x201D; &#x2014; Givi Misure" data-secret="gzWTPUs5WT" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script&gt;
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://www.givimisureindia.com/wp-includes/js/wp-embed.min.js
&lt;/script&gt;
</html><description>VI900 &#x2013; Multi-axis digital readout, with touch-screen color LCD, for absolute and incremental systems Overview Compact-design, modern and functional digital readout, equipped with the new Absolute Warning System (AWS). AWS constantly guarantees the correctness of the displayed positions and informs the operator of any malfunctioning. The user can continue machining or, based on the error message displayed, intervene to restore the proper functioning of the system. Absolute (SSI protocol) or incremental encoder input signals. 5.7&#x201D; touch-screen color, LED-backlit, LCD TFT panel which allows the displaying of up to 4 axes. USB, Touch Probe, CAN bus and serial RS-232 interfaces. Resolutions up to 0.1 &#x3BC;m. Online HELP. Graphic visualization of function execution. Diagnostic of readout and encoders. Reading of coded reference indexes. Absolute signals RS-422: Clock+, Clock-, Data+, Data-. Universal software for any kind of machine tool; updates through serial port. 1000 memory blocks. Possibility of connection to a digital (up to 8 relay outputs) or analog (constant surface speed) remote board. Option: flush-mounted version (on a panel). MODELS VI900 Touch-screen color LCD display RB900 I/O Digital remote board &#x2013; Up to 8 relay outputs New RB900 CSS Analog remote board &#x2013; Constant surface speed New VI900 Touch-screen color LCD display Display 5.7&#x201D; color, LED-backlit LCD TFT Incremental encoder input signals 2 square waves with phase displacementof 90&#xB0; &#xB1; 5&#xB0; + synchronized index 5 Vdc Absolute (SSI) encoder input signals RS-422: Clock+, Clock-, Data+, Data- Available resolutions 1,000 &#x2013; 500 &#x2013; 200 &#x2013; 100 &#x2013; 50 &#x2013; 20 &#x2013; 10 &#x2013; 5 &#x2013; 2 &#x2013; 1 &#x2013;0.5 &#x2013; 0.2 &#x2013; 0.1 &#x3BC;m1&#xB0; &#x2013; 0.5&#xB0; &#x2013; 0.2&#xB0; &#x2013; 0.1&#xB0; &#x2013; 0.05&#xB0; &#x2013; 0.02&#xB0; &#x2013; 0.01&#xB0; &#x2013;0.005&#xB0; &#x2013; 0.002&#xB0; &#x2013; 0.001&#xB0; Protection class &#xA0;IP 40 IP 54 with plastic cover provided Input axes 2 &#x2013; 3 &#x2013; 4 Applicable to lathe &#x2013; milling machine &#x2013; boring machine &#x2013; etc. Power supply 230 Vac &#xB1; 10% &#x2013; 50/60 Hz 60 mAMAX110 Vac &#xB1; 10% &#x2013; 60 Hz 120 mAMAX24 Vac &#xB1; 10% &#x2013; 50/60 Hz 500 mAMAX Version standard or flush-mounted Options CAN interface Download Brochure &#x2193; RB900 I/O Digital remote board &#x2013; Up to 8 relay outputs New Power supply from VI900 5 Vdc &#xB1; 10% &#xA0;External power supply (PWS) &#xA0;12 &#x2013; 24 Vac &#xB1; 10% &#x2013; 50/60 Hz12 &#x2013; 24 Vdc &#xB1; 10% &#xA0;Power &#xA0;1.5 WMAX &#xA0;Current consumption &#xA0;240 mAMAX (5 Vdc from VI900)60 mAMAX (24 Vdc from external power supply PWS) Inputs &#xA0; VinHIGH= 4.5 &#xF7; 30 Vdc VinLOW= 0 &#xF7; 2 VdctMIN= 100 msoptoisolated and independent &#xA0;Digital outputs static N.O. relay contacts, 60 Vac/dcMAX, 0.6 AMAX,0.36 WMAXprotected against overload and overcurrent Connections D-SUB 15p M (COM1)terminal block 3p M (external power supply PWS)terminal block 12p M (input/output) Protection class IP 20 Download Brochure &#x2193; RB900 CSS Analog remote board &#x2013; Constant surface speed New Power supply from VI900 5 Vdc &#xB1; 10% &#xA0;External power supply (PWS) &#xA0;12 &#x2013; 24 Vac &#xB1; 10% &#x2013; 50/60 Hz12 &#x2013; 24 Vdc &#xB1; 10% &#xA0;Power &#xA0;1.5 WMAX &#xA0;Current consumption &#xA0;240 mAMAX (5 Vdc from VI900)60 mAMAX (24 Vdc from external power supply PWS) Analog output &#xA0;0 &#x2013; 10 Vdc Connections D-SUB 15p M (COM1)terminal block 3p M (external power supply PWS)terminal block 12p M (input/output) Protection class IP 20 Download Brochure &#x2193; ISA 10 Resolution 100 &#xB5;m ISA 100 Resolution 10 &#xB5;m ISA 5 Resolution 5 &#xB5;m ISA W1 Resolution 1 &#xB5;m Resolution : 100 &#xB5;m Resolution : 10 &#xB5;m Resolution : 5 &#xB5;m Resolution : 1 &#xB5;m Grating pitch : 400 &#xB5;m Grating pitch : 40 &#xB5;m Grating pitch : 20 &#xB5;m Grating pitch : 40 &#xB5;m Accuracy grade : &#xB1; 10 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Max. traversing speed : 120 m/min Max. traversing speed : 80 m/min Max. traversing speed : 60 m/min Max. traversing speed : 25 m/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure</description><thumbnail_url>https://techsparktechnologies.in/givimisure/wp-content/uploads/2026/01/v900.png</thumbnail_url></oembed>
