<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Givi Misure</provider_name><provider_url>https://www.givimisureindia.com</provider_url><author_name>wpsuperadmin-givimisure</author_name><author_url>https://www.givimisureindia.com/index.php/author/wpsuperadmin-givimisure/</author_url><title>GVS 808 - Givi Misure</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="5DGn6RAPtM"&gt;&lt;a href="https://www.givimisureindia.com/index.php/gvs-808/"&gt;GVS 808&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://www.givimisureindia.com/index.php/gvs-808/embed/#?secret=5DGn6RAPtM" width="600" height="338" title="&#x201C;GVS 808&#x201D; &#x2014; Givi Misure" data-secret="5DGn6RAPtM" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script&gt;
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://www.givimisureindia.com/wp-includes/js/wp-embed.min.js
&lt;/script&gt;
</html><description>GVS 808 Absolute linear encoder for CNC machine tools Overview Absolute optical encoder with glass measuring support. Serial interface SSI &#x2013; BiSS C (unidirectional), with or without 1 Vpp analog signal, Siemens DRIVE-CLiQ, FANUC &#x3B1;i and MITSUBISHI High Speed. Resolutions up to 1 nm. Accuracy grade &#xB1; 5 &#x3BC;m in the standard version and &#xB1; 3 &#x3BC;m in the high accuracy version (&#xB1; 2 &#x3BC;m for measuring lengths up to 640 mm). Option: Innovative Fixed Expansion Point (FEP), in the middle, positionable on the right (RT) or on the left (LT), for a linear expansion consistent with the type of application. Double pair of linear sealing lips for a very high protection of the grating. Metrological certificate provided with each scale. Linear thermal expansion coefficient &#x3BB; = 8 x 10-6 &#xB0;C-1. Direct reading of the absolute measure. Connector on the transducer (IP 67), easily disconnectable in case of need. Protected against inversion of power supply polarity and short circuits on output ports. Rugged and heavy profile of considerable section, made of anodized aluminum. Adjustable cable output, through double connector. Pressurization from both sides of the scale or from the transducer. Models GVS 808 T GVS 808 D GVS 808 F GVS 808 M GVS 808 T Serial interface SSI &#x2013; BiSS Download Brochure &#x2193; GVS 808 D Serial interface Siemens DRIVE-CLiQ Download Brochure &#x2193; GVS 808 F Serial interface FANUC &#x3B1;i Download Brochure &#x2193; GVS 808 M Serial interface MITSUBISHI High Speed Download Brochure &#x2193; ISA 10 Resolution 100 &#xB5;m ISA 100 Resolution 10 &#xB5;m ISA 5 Resolution 5 &#xB5;m ISA W1 Resolution 1 &#xB5;m Resolution : 100 &#xB5;m Resolution : 10 &#xB5;m Resolution : 5 &#xB5;m Resolution : 1 &#xB5;m Grating pitch : 400 &#xB5;m Grating pitch : 40 &#xB5;m Grating pitch : 20 &#xB5;m Grating pitch : 40 &#xB5;m Accuracy grade : &#xB1; 10 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Max. traversing speed : 120 m/min Max. traversing speed : 80 m/min Max. traversing speed : 60 m/min Max. traversing speed : 25 m/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure</description><thumbnail_url>https://techsparktechnologies.in/givimisure/wp-content/uploads/2026/01/808.png</thumbnail_url></oembed>
