<br />
<b>Warning</b>:  Attempt to read property "ID" on null in <b>/home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php</b> on line <b>51</b><br />
<br />
<b>Warning</b>:  Cannot modify header information - headers already sent by (output started at /home/o1cbletemrwq3bju/public_html/wp-content/plugins/wp-social/inc/share.php:51) in <b>/home/o1cbletemrwq3bju/public_html/wp-includes/rest-api/class-wp-rest-server.php</b> on line <b>1902</b><br />
<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Givi Misure</provider_name><provider_url>https://www.givimisureindia.com</provider_url><title>AGM - Givi Misure</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="D1sXEAxwAp"&gt;&lt;a href="https://www.givimisureindia.com/index.php/agm/"&gt;AGM&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://www.givimisureindia.com/index.php/agm/embed/#?secret=D1sXEAxwAp" width="600" height="338" title="&#x201C;AGM&#x201D; &#x2014; Givi Misure" data-secret="D1sXEAxwAp" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script&gt;
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://www.givimisureindia.com/wp-includes/js/wp-embed.min.js
&lt;/script&gt;
</html><description>AGM Absolute magnetic sensor with serial interface SSI &#x2013; BiSS, CANopen or FANUC Overview Linear magnetic sensor, with direct reading of the absolute position. High performance, with a measuring length up to 30,000 mm. Resolutions up to 1 &#x3BC;m and repeatability &#xB1; 1 increment. Extremely easy and fast mounting of the entire measuring system, with wide alignment tolerances and sensor/magnetic band gap up to 1 mm. Serial interface SSI &#x2013; BiSS protocol (with or without 1 Vpp analog signal), CANopen or FANUC &#x3B1;i with programmable resolutions. Profibus-DP, Profinet, DeviceNet, ModBus and DRIVE-CLiQ protocols, through conversion gateways. High-speed serial data transfer. Small-sized, for applications with limited installation space. Magnetic band width 10 mm. Insensitive to dust and liquids (IP 67 protection class). Magnetic sensor body made of die-cast metallic material. High signal stability, even with high speed and accelerations. Cable suitable for continuous movements. Axial or radial cable output. Protected against inversion of power supply polarity and short circuits on output ports. Warning indication through LED. Brochure Models AGM-2 SSI &#x2013; BiSS AGM-2 FANUC AGM CANopen AGM-2 SSI &#x2013; BiSS Pole pitch &#xA0;1+1 mm Serial interface SSI &#x2013; BiSS interface Download Brochure &#x2193; AGM-2 FANUC Pole pitch &#xA0;2+2 mm Serial interface FANUC &#x3B1;i interface Download Brochure &#x2193; AGM CANopen Pole pitch &#xA0;2+2 mm Serial interface CANopen interface Download Brochure &#x2193; ISA 10 Resolution 100 &#xB5;m ISA 100 Resolution 10 &#xB5;m ISA 5 Resolution 5 &#xB5;m ISA W1 Resolution 1 &#xB5;m Resolution : 100 &#xB5;m Resolution : 10 &#xB5;m Resolution : 5 &#xB5;m Resolution : 1 &#xB5;m Grating pitch : 400 &#xB5;m Grating pitch : 40 &#xB5;m Grating pitch : 20 &#xB5;m Grating pitch : 40 &#xB5;m Accuracy grade : &#xB1; 10 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Accuracy grade : &#xB1; 5 &#xB5;m Max. traversing speed : 120 m/min Max. traversing speed : 80 m/min Max. traversing speed : 60 m/min Max. traversing speed : 25 m/min Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Reference indexes : in required positions Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Output signals : NPN / LINE DRIVER / PUSH-PULL Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Protection class : IP 53 standard IP 64 pressurized Downlod Brochure Downlod Brochure Downlod Brochure Downlod Brochure</description><thumbnail_url>https://techsparktechnologies.in/givimisure/wp-content/uploads/2026/01/agm.png</thumbnail_url></oembed>
