vision518 2017-12-13T09:03:32+00:00

DIGITAL READOUTS

VI518 – Single-axis digital readout, for absolute and incremental systems

  • Compact-design, single-axis digital readout, equipped with the new Absolute Warning System (AWS).
  • AWS constantly guarantees the correctness of the displayed positions and informs the operator of any malfunctioning. The user can continue machining or, based on the error message displayed, intervene to restore the proper functioning of the system.
  • Suitable for several machine tools, such as those performing cutting or machining at a preset size, polishing, bending, grinding or traightening.
  • Applicable on various industries, such as wood, sheet metal, marble, rubber, textile and automation.
  • Absolute (SSI protocol) or incremental encoder input signals.
  • Up to 8 digits displayed, including floating decimal point and negative sign.
  • Device diagnostic.
  • Internal rewritable memory.
  • Absolute signals RS-422: Clock+, Clock-, Data+, Data-.
  • Resolutions up to 0.5 μm.
  • Correction factor, angular reading, programmable relay outputs and many other functions available.
  • Serial output RS-232, for the transmission of positions.
  • Panel mountable version available.

VI518 Standard version

VI518 Version with options

Display 8 high-efficiency digits h = 13 mm
Incremental Encoder input signals 2 square waves with phase displacement of 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
Power supply  230 Vac ± 10% – 50/60 Hz 40 mA
110 Vac ± 10% – 60 Hz 80 mA
24 Vac ± 10% – 50/60 Hz 350 mA
 Memory  permanent for configuration
and “user” settings
(last data operating memory)
Available resolutions 200 – 100 – 50 – 20 – 10 – 5 – 2 – 1 – 0.5 μm
1° – 0.5° – 0.2° – 0.1° – 0.05° – 0.02° – 0.01° – 0.005° – 0.002° – 0.001°
Download Brochure

Display 8 high-efficiency digits h = 13 mm
Incremental Encoder input signals 2 square waves with phase displacement of 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
Absolute (SSI) encoder input signals RS-422: Clock+, Clock-, Data+, Data-
Power supply  230 Vac ± 10% – 50/60 Hz 40 mA
110 Vac ± 10% – 60 Hz 80 mA
24 Vac ± 10% – 50/60 Hz 350 mA
 Memory  permanent for configuration
and “user” settings
(last data operating memory)
Available resolutions 200 – 100 – 50 – 20 – 10 – 5 – 2 – 1 – 0.5 μm
1° – 0.5° – 0.2° – 0.1° – 0.05° – 0.02° – 0.01° – 0.005° – 0.002° – 0.001°
Options serial output RS-232
relay outputs
static relays AC – static relays DC
absolute (SSI) encoder input
Download Brochure
  • SELF-TESTING
  • LOAD POSITION PRESET
  • POSITION RESET/PRESET
  • ABSOLUTE/INCREMENTAL COUNTING
  • VARIABLE RESOLUTION
  • RADIUS/DIAMETER CONVERSION
  • MM/INCH CONVERSION
  • SCALE ZERO REFERENCE (REF)
  • DISABLING SCALE ZERO REFERENCE
  • COUNTING MODE (x1, x2, x4)
  • INVERSION OF COUNTING DIRECTION
  • MIDPOINT CALCULATION
  • SETTING SSI PARAMETERS
  • MEMORY CLEARING
  • LINEAR CORRECTION
  • ANGULAR READING
  • SEXAGESIMAL DEGREES READING
  • RELAY OUTPUTS ACTIVATION (opt.)
  • SETTING TIMED RELAY OUTPUTS (opt.)
  • SETTING INTERVENTION POSITIONS (opt.)
  • RS-232 SERIAL OUTPUT (opt.)
  • ENABLING THE AUTOMATIC TRANSMISSION OF POSITIONS