VISION110 2017-12-13T06:50:46+00:00

MAGNETIC SYSTEMS

VISION 110 – Digital readout with magnetic sensor

  • One-axis digital readout, with 6 ½ digit LCD and negative sign.
  • Metal sensor body of small overall dimensions.
  • Fixing of magnetic sensor by existing threaded holes M4 or by M3 through screws.
  • Power supply either via battery or external.
  • Flexible cable max. length 4 m.
  • Wide alignment tolerances.
  • Several user-friendly functions available.
  • Available in two different models:
    • VISION 110S: digital readout body of standard dimension, for drilling template 92×44 mm.
    • VISION 110L: digital readout body of standard dimensions and front of bigger size, for mounting on panel with drilling template 92×66 mm, or adjustable for standard drilling template (92×44 mm).
  • To be used with magnetic band MP200 or MP100.

VISION 110 S Small version

VISION 110 L Large version

Suitable for drilling template (lxh) 92×44 mm
Display 6 ½ digit h = 13 mm
Programmable resolutions 1 – 0.1 – 0.05 – 0.01 mm
0.01 – 0.001 – 1/16 – 1/32 – 1/64 inches
1° – 0.1° – 0.01° – 0.001° angular
Power supply 3 V (2 AA batteries)
1.5 ÷ 5 V (external)
In combination with magnetic band MP100 MP200
Pole pitch 1+1 mm 2+2 mm
Max. counting speed 2 m/s 4 m/s
Sensor – magnetic band gap 0.1 ÷ 0.4 mm 0.3 ÷ 2 mm
Accuracy ± 15 μm ± 20 μm
Sensor’s protection class IP 67 IP 67
Download Brochure

Suitable for drilling template (lxh) 92×44 mm – 92×66 mm
Display 6 ½ digit h = 13 mm
Programmable resolutions 1 – 0.1 – 0.05 – 0.01 mm
0.01 – 0.001 – 1/16 – 1/32 – 1/64 inches
1° – 0.1° – 0.01° – 0.001° angular
Power supply 3 V (2 AA batteries)
1.5 ÷ 5 V (external)
In combination with magnetic band MP100 MP200
Pole pitch 1+1 mm 2+2 mm
Max. counting speed 2 m/s 4 m/s
Sensor – magnetic band gap 0.1 ÷ 0.4 mm 0.3 ÷ 2 mm
Accuracy ± 15 μm ± 20 μm
Sensor’s protection class IP 67 IP 67
Download Brochure
  • SELF-TESTING
  • DEVICE DIAGNOSTIC
  • AXIS RESOLUTION SELECTION
  • RESET/PRESET OF AN INCR./ABS. POSITION
  • SETTING AN INCR./ABS. “REF” POSITION
  • SETTING TIME FOR THE DEVICE SELF-SWITCHING OFF
  • INVERSION OF COUNTING DIRECTION
  • LINEAR CORRECTION
  • ABSOLUTE/INCREMENTAL COUNTING
  • SETTING TIME FOR DISPLAY STAND-BY
  • PARAMETERS’ ACCESS PASSWORD MODIFICATION
  • SETTING FREE CALCULATION FACTOR